Pre-Trip Safety & Grounding Audit Trail

Inspection # / Date Equipment Asset Lead Inspector Mechanical Checks Boom Hydraulics Earthing & PPE Safety Verdict Inspector Notes
DVIR-2026-09-04
2026-09-21 07:30:00
WP CP-1102
Kato 25-Ton Rough Terrain Hydraulic Crane
G.A. Kamal Pushpakumara
Meter: 4120.0
Passed Passed Certified Cleared Load test indicator calibrated, outrigger safety pins locked, ground mats in place.
DVIR-2026-09-03
2026-09-20 07:00:00
WP DA-7844
Mahindra Bolero Camper 4x4
B.M. Nihal Bandara
Meter: 112450.0
Fault Defect Certified Grounded Front right tire sidewall blister detected; Brake pedal travel excessive and spongy. Flagged vehicle out of service.
DVIR-2026-09-02
2026-09-21 07:10:00
WP NA-4521
Isuzu Elf / Aichi 16m Insulated Live-Line Boom Lift
M.R. Chandrasiri
Meter: 2180.0
Passed Passed Certified Advisory Slight hydraulic oil seepage at secondary boom swivel joint. Level acceptable. Monitored during shift.
DVIR-2026-09-01
2026-09-21 06:45:00
WP CAB-5521
Toyota Hilux Double Cab 4x4
K.G. Sunil Shantha
Meter: 74210.0
Passed Passed Certified Cleared All systems verified before Peliyagoda to Kerawalapitiya shift.